Department | 光电工程总体研究室(一室) |
Using Allan Variance Based Semi-Parameter Model to Calibrate Pointing Errors of Alt-az Telescopes | |
Lingjie Yan1,2,3; Yongmei Huang1,2; Yahui Zhang1,2 | |
Source Publication | APPLIED SCIENCES-BASEL
![]() |
Volume | 8Issue:4Pages:614 |
2018-04-01 | |
Language | 英语 |
ISSN | 2076-3417 |
DOI | 10.3390/app8040614 |
Indexed By | SCI |
WOS ID | WOS:000434996400141 |
Subtype | J |
Abstract | In this paper, a new model called Allan variance based semi-parameter model is put forward to improve the pointing precision for alt-az telescopes. As for electro-optical tracking systems, the precision of line-of-sight (LOS) pointing is seriously influenced by both geometric and nonlinear error sources. In modeling part of the parameter model, a simplified mount model is set up to demonstrate impacts of geometric errors that are caused by imprecision during mechanical processes on LOS pointing, according to values of encoders and miss distances in charge-coupled-device (CCD) cameras. Considering the limitations of mount models, an improved hybrid model called the Allan variance based semi-parameter model is introduced to compensate for residual nonlinear errors in the calibration portion. Compared with the classical mount model, the Allan variance based semi-parameter model removes both geometric errors and nonlinear errors, and the LOS pointing precision has been remarkably improved after calibration of the proposed model. |
Keyword | alt-az telescopes LOS pointing errors nonlinear error mount model Allan variance Allan variance based semi-parameter model |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.ioe.ac.cn/handle/181551/9263 |
Collection | 光电工程总体研究室(一室) |
Affiliation | 1.Key Laboratory of Optical Engineering, Chinese Academy of Sciences, Chengdu 610209, China; 2.Institute of Optics and Electronics, Chinese Academy of Science, Chengdu 610209, China; 3.College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100039, China |
Recommended Citation GB/T 7714 | Lingjie Yan,Yongmei Huang,Yahui Zhang. Using Allan Variance Based Semi-Parameter Model to Calibrate Pointing Errors of Alt-az Telescopes[J]. APPLIED SCIENCES-BASEL,2018,8(4):614. |
APA | Lingjie Yan,Yongmei Huang,&Yahui Zhang.(2018).Using Allan Variance Based Semi-Parameter Model to Calibrate Pointing Errors of Alt-az Telescopes.APPLIED SCIENCES-BASEL,8(4),614. |
MLA | Lingjie Yan,et al."Using Allan Variance Based Semi-Parameter Model to Calibrate Pointing Errors of Alt-az Telescopes".APPLIED SCIENCES-BASEL 8.4(2018):614. |