IOE OpenIR  > 自适应光学技术研究室(八室)
Statistical analysis of ocular monochromatic aberrations in Chinese population for adaptive optics ophthalmoscope design
Zhao, Junlei1,2,3; Xiao, Fei1,2,3; Kang, Jian1,2,3; Zhao, Haoxin1,2; Dai, Yun1,2; Zhang, Yudong1,2
2017
发表期刊Journal of Innovative Optical Health Sciences
ISSN1793-5458
卷号10期号:1页码:1650038
摘要It is necessary to know the distribution of the Chinese eye's aberrations in clinical environment to guide high-resolution retinal imaging system design for large Chinese population application. We collected the monochromatic wave aberration of 332 healthy eyes and 344 diseased eyes in Chinese population across a 6.0-mm pupil. The aberration statistics of Chinese eyes including healthy eyes and diseased eyes were analyzed, and some differences of aberrations between the Chinese and European race were concluded. On this basis, the requirement for adaptive optics (AO) correction of the Chinese eye's monochromatic aberrations was analyzed. The result showed that a stroke of 20μm and ability to correct aberrations up to the 8th Zernike order were needed for reflective wavefront correctors to achieve near diffraction-limited imaging in both groups for a reference wavelength of 550nm and a pupil diameter of 6.0mm. To verify the analysis mentioned above, an AO flood-illumination system was established, and high-resolution retinal imaging in vivo was achieved for Chinese eye including both healthy and diseased eyes. © 2017 The Author(s).
关键词Aberrations - Image resolution - Imaging systems - Ophthalmology - Optical devices - Population statistics - Vision aids
收录类别SCI ; Ei
语种英语
文献类型期刊论文
条目标识符http://ir.ioe.ac.cn/handle/181551/8823
专题自适应光学技术研究室(八室)
作者单位1.Laboratory on Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu; 610209, China;
2.Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu; 610209, China;
3.University of Chinese Academy of Sciences, Beijing; 100049, China
推荐引用方式
GB/T 7714
Zhao, Junlei,Xiao, Fei,Kang, Jian,et al. Statistical analysis of ocular monochromatic aberrations in Chinese population for adaptive optics ophthalmoscope design[J]. Journal of Innovative Optical Health Sciences,2017,10(1):1650038.
APA Zhao, Junlei,Xiao, Fei,Kang, Jian,Zhao, Haoxin,Dai, Yun,&Zhang, Yudong.(2017).Statistical analysis of ocular monochromatic aberrations in Chinese population for adaptive optics ophthalmoscope design.Journal of Innovative Optical Health Sciences,10(1),1650038.
MLA Zhao, Junlei,et al."Statistical analysis of ocular monochromatic aberrations in Chinese population for adaptive optics ophthalmoscope design".Journal of Innovative Optical Health Sciences 10.1(2017):1650038.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
2017-2063.pdf(808KB)期刊论文出版稿开放获取CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhao, Junlei]的文章
[Xiao, Fei]的文章
[Kang, Jian]的文章
百度学术
百度学术中相似的文章
[Zhao, Junlei]的文章
[Xiao, Fei]的文章
[Kang, Jian]的文章
必应学术
必应学术中相似的文章
[Zhao, Junlei]的文章
[Xiao, Fei]的文章
[Kang, Jian]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。