IOE OpenIR  > 自适应光学技术研究室(八室)
Quantifying intraocular scatter with near diffraction-limited double-pass point spread function
Zhao, Junlei1,2,3; Xiao, Fei1,2; Kang, Jian1,2,3; Zhao, Haoxin1,2; Dai, Yun1,2; Zhang, Yudong1,2
2016
发表期刊Biomedical Optics Express
ISSN2156-7086
卷号7期号:11页码:4595-4604
文章类型J
摘要Measurement of the double-pass (DP) point-spread function (PSF) can provide an objective and non-invasive method for estimating intraocular scatter in the human eye. The objective scatter index (OSI), which is calculated from the DP PSF images, is commonly used to quantify intraocular scatter. In this article, we simulated the effect of higher-order ocular aberrations on OSI, and the results showed that higher-order ocular aberrations had a significant influence on OSI. Then we developed an adaptive optics DP PSF measurement system (AO-DPPMS) which was capable of correcting ocular aberrations up to eighth-order radial Zernike modes over a 6.0-mm pupil. Employing this system, we obtained DP PSF images of four subjects at the fovea. OSI values with aberrations corrected up to 2nd, 5th and 8th Zernike order were calculated respectively, from the DP PSF images of the four subjects. The experimental results were consistent with the simulation, suggesting that it is necessary to compensate for the higher-order ocular aberrations for accurate intraocular scatter estimation. © 2016 Optical Society of America.
关键词Adaptive Optics Imaging Systems Noninvasive Medical Procedures
DOI10.1364/BOE.7.004595
收录类别SCI ; Ei
语种英语
项目资助者National Natural Science Foundation of China [61378064] ; National High Technology Research and Development Program of China [2015AA020511]
WOS记录号WOS:000387557600020
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ioe.ac.cn/handle/181551/8423
专题自适应光学技术研究室(八室)
作者单位1. The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu
2.610209, China
3. The Laboratory on Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu
4.610209, China
5. University of Chinese Academy of Sciences, Beijing
6.100049, China
推荐引用方式
GB/T 7714
Zhao, Junlei,Xiao, Fei,Kang, Jian,et al. Quantifying intraocular scatter with near diffraction-limited double-pass point spread function[J]. Biomedical Optics Express,2016,7(11):4595-4604.
APA Zhao, Junlei,Xiao, Fei,Kang, Jian,Zhao, Haoxin,Dai, Yun,&Zhang, Yudong.(2016).Quantifying intraocular scatter with near diffraction-limited double-pass point spread function.Biomedical Optics Express,7(11),4595-4604.
MLA Zhao, Junlei,et al."Quantifying intraocular scatter with near diffraction-limited double-pass point spread function".Biomedical Optics Express 7.11(2016):4595-4604.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
2016-2018.pdf(2250KB)期刊论文作者接受稿开放获取CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhao, Junlei]的文章
[Xiao, Fei]的文章
[Kang, Jian]的文章
百度学术
百度学术中相似的文章
[Zhao, Junlei]的文章
[Xiao, Fei]的文章
[Kang, Jian]的文章
必应学术
必应学术中相似的文章
[Zhao, Junlei]的文章
[Xiao, Fei]的文章
[Kang, Jian]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。