Abstract | In this paper, a method for the focal length measurement of Microlens-array (MLA) is introduced. The measuring setup is composed by monochromatic, condenser, collimator, MLA, microscope and CCD sensor. An experiment was performed using a MLA whose focal length is about 8 mm and a GUI based on Matlab software was developed to analyze the image gathered at the vertex and the focus by the clarity of digital image processing technology. The measuring uncertainty of this method is about 0.8% and this method introduced in this paper can finish tens of microlens array measurement at a single shot. Compared with traditional technology for MLA measuring, this method not only has a preferable precision but also super efficiency. © 2012 SPIE.; In this paper, a method for the focal length measurement of Microlens-array (MLA) is introduced. The measuring setup is composed by monochromatic, condenser, collimator, MLA, microscope and CCD sensor. An experiment was performed using a MLA whose focal length is about 8 mm and a GUI based on Matlab software was developed to analyze the image gathered at the vertex and the focus by the clarity of digital image processing technology. The measuring uncertainty of this method is about 0.8% and this method introduced in this paper can finish tens of microlens array measurement at a single shot. Compared with traditional technology for MLA measuring, this method not only has a preferable precision but also super efficiency. © 2012 SPIE. |
Conference Name | Proceedings of SPIE: 6th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment |
Conference Date | 2012 |
Citation statistics | |
Document Type | 会议论文 |
Identifier | http://ir.ioe.ac.cn/handle/181551/7916 |
Collection | 质量处(质检中心) |
Corresponding Author | Zhu, X. |
Affiliation | Institute of Optics and Electronics, Chinese Academy of Science, Chengdu, Sichuan, 610209, China |
Recommended Citation GB/T 7714 | Zhu, Xianchang,Wu, Zhu Fan,Cao, Xuedong,et al. Focal length measurement of Microlens-array by the clarity function of digital image[C],2012:84171E. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License | ||
2012-2146.pdf(1222KB) | 会议论文 | 开放获取 | CC BY-NC-SA | Application Full Text |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment