Experimental resolution comparison between the TOMBO and single lens systems | |
Gao, Yuan1,2; Yang, Ping1; Tang, Guomao1; Xua, Bing1; Ao, Mingwu3 | |
Volume | 9227 |
Pages | 92270B |
2014 | |
Language | 英语 |
ISSN | 0277786X |
DOI | 10.1117/12.2061316 |
Indexed By | Ei |
Subtype | 会议论文 |
Abstract | Thin observation module by bounded optics (TOMBO) is an optical system substituting a micro lens-let array with smaller apertures for a conventional large full aperture. This array allows us to capture multiple low resolution sub-images of the same scene and use them to reconstruct a high resolution image. While lost resolutions can be recovered, there has been very little work on experimentally evaluating restored resolution performance in the TOMBO system. Our work focuses on resolution comparisons among a 4×4 lens-let TOMBO and Nikon lenses in the same f number condition. Experimental results present the equivalent focal length of the experimental TOMBO system. © 2014 SPIE.; Thin observation module by bounded optics (TOMBO) is an optical system substituting a micro lens-let array with smaller apertures for a conventional large full aperture. This array allows us to capture multiple low resolution sub-images of the same scene and use them to reconstruct a high resolution image. While lost resolutions can be recovered, there has been very little work on experimentally evaluating restored resolution performance in the TOMBO system. Our work focuses on resolution comparisons among a 4×4 lens-let TOMBO and Nikon lenses in the same f number condition. Experimental results present the equivalent focal length of the experimental TOMBO system. © 2014 SPIE. |
Conference Name | Proceedings of SPIE: Unconventional Imaging and Wavefront Sensing 2014 |
Conference Date | 2014 |
Citation statistics | |
Document Type | 会议论文 |
Identifier | http://ir.ioe.ac.cn/handle/181551/7827 |
Collection | 自适应光学技术研究室(八室) |
Affiliation | 1. Laboratory on Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China 2. University of Chinese Academy of Sciences, Beijing, China 3. University of Electronic Science and Technology of China, Chengdu, China |
Recommended Citation GB/T 7714 | Gao, Yuan,Yang, Ping,Tang, Guomao,et al. Experimental resolution comparison between the TOMBO and single lens systems[C],2014:92270B. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License | ||
2014-2173.pdf(817KB) | 会议论文 | 开放获取 | CC BY-NC-SA | Application Full Text |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment