A method to improve the precision of measuring focusing system
Xu, Xiaoliang1,2,3; An, Tao1,2; Chen, Ke1,2
Volume9678
2015
Language英语
ISSN0277-786X
DOI10.1117/12.2197234
Indexed ByEi
Subtype会议论文
AbstractMost of the telescope focusing systems adopt the measuring distance method to focus the quick-moving target because the imaging position of moving target is constantly changing. The focusing system calculates the focal position, controls the motor according to the distance of the target. This focusing method has a faster focusing and a better real-time performance compared to the image focusing method based on the image quality. But restricted by the external environment, the precision of instruments and technical level, Distance measuring focus system(DMFS) generally have low precision, higher dynamic adjusting delay problem. This paper mainly analyses the main error sources affecting the accuracy of DMFS, aiming at the existing defects of commonly used current speed compensation method, put forward a kind of solution path delay lag method predicted method measuring focusing system, and then simulate it, the result shows that this method can greatly improve the precision of DMFS. © 2015 SPIE.; Most of the telescope focusing systems adopt the measuring distance method to focus the quick-moving target because the imaging position of moving target is constantly changing. The focusing system calculates the focal position, controls the motor according to the distance of the target. This focusing method has a faster focusing and a better real-time performance compared to the image focusing method based on the image quality. But restricted by the external environment, the precision of instruments and technical level, Distance measuring focus system(DMFS) generally have low precision, higher dynamic adjusting delay problem. This paper mainly analyses the main error sources affecting the accuracy of DMFS, aiming at the existing defects of commonly used current speed compensation method, put forward a kind of solution path delay lag method predicted method measuring focusing system, and then simulate it, the result shows that this method can greatly improve the precision of DMFS. © 2015 SPIE.
Conference NameProceedings of SPIE - The International Society for Optical Engineering
Conference Date2015
Citation statistics
Document Type会议论文
Identifierhttp://ir.ioe.ac.cn/handle/181551/7428
Collection光电工程总体研究室(一室)
Affiliation1. Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, Sichuan, China
2. Key Laboratory of Optical Engineering, Chinese Academy of Sciences, Chengdu, Sichuan, China
3. University of Chinese Academy of Sciences, Beijing, China
Recommended Citation
GB/T 7714
Xu, Xiaoliang,An, Tao,Chen, Ke. A method to improve the precision of measuring focusing system[C],2015.
Files in This Item:
File Name/Size DocType Version Access License
2015-2178.pdf(328KB)会议论文 开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Xu, Xiaoliang]'s Articles
[An, Tao]'s Articles
[Chen, Ke]'s Articles
Baidu academic
Similar articles in Baidu academic
[Xu, Xiaoliang]'s Articles
[An, Tao]'s Articles
[Chen, Ke]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Xu, Xiaoliang]'s Articles
[An, Tao]'s Articles
[Chen, Ke]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.